{"product_id":"netafim-tlhcvxr-rw5-1205-netafim-techline-hcvxr-17-mm-reclaimed-purple-stripe-check-valve-dripline-0-53-gph-12-in-spacing-500-ft","title":"Netafim Techline HCVXR 17 mm Reclaimed Purple Stripe Check Valve Dripline 0.53 gph 12 in. Spacing 500 ft. - TLHCVXR-RW5-1205","description":"\u003cdiv style=\"text-align: left;\"\u003e\n\u003ch2\u003eNetafim Techline HCVXR 17 mm Reclaimed Purple Stripe Check Valve Dripline 0.53 gph 12 in. Spacing 500 ft. - TLHCVXR-RW5-1205\u003c\/h2\u003e\n\u003cp\u003eTECHLINE HCVXR-RW IS DESIGNED FOR RECLAIMED WATER USE ONLY Reclaimed, reused or recycled water is municipally-treated, non-potable water deemed appropriate for use in irrigation systems and not wastewater being dispersed into the soil for additional treatment. Please consult your local Water Management District for regulations regarding the type of water being used, and its proper system design. Netafim USA can provide assistance on drip dispersal that uses primary or secondary and tertiary wastewater. Please contact Netafim USA Customer Service for more information.\u003c\/p\u003e\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eEmitter flows: 0.33, 0.53, 0.77, 1.16 GPH\u003c\/li\u003e\n\u003cli\u003eEmitter spacings: 12” and 18”\u003c\/li\u003e\n\u003cli\u003ePressure compensation range: 21.8 to 58 psi\u003c\/li\u003e\n\u003cli\u003eHigh check valve: holds back 8.5’ of water\u003c\/li\u003e\n\u003cli\u003eBending radius: 7”\u003c\/li\u003e\n\u003cli\u003eMaximum recommended system pressure: 58 psi\u003c\/li\u003e\n\u003cli\u003eMinimum pressure required: 21.8 psi\u003c\/li\u003e\n\u003cli\u003eTubing diameter: 0.66” OD; 0.56” ID, 0.050” wall\u003c\/li\u003e\n\u003cli\u003eCoil lengths: 250’ and 1,000’\u003c\/li\u003e\n\u003cli\u003eRecommended minimum filtration: 120 mesh\u003c\/li\u003e\n\u003cli\u003eDiaphragm: molded silicon • ISO 9261 Standard Compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\u003cstrong\u003eDocuments\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1987\/5531\/files\/73CD8974-B897-4FED-AA1D60D4B68404EF-tlhcvxr-rw-techline-hcvxr-rw.pdf?v=1648614836\" title=\"Netafim - TLHCVXR-RW5-1205 - Netafim Techline HCVXR 17 mm Reclaimed Purple Stripe Check Valve Dripline 0.53 gph 12 in. Spacing 500 ft.\"\u003eTechnical Specs\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003eWhat Our Experts Think\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-start=\"29\" data-end=\"229\"\u003e\n\u003cstrong data-start=\"31\" data-end=\"56\"\u003eReclaimed Water Ready\u003c\/strong\u003e: The Netafim Techline HCVXR 17mm Dripline (TLHCVXR-RW5-1205) is designed for reclaimed water use, marked with a purple stripe for easy identification in irrigation systems.\u003c\/li\u003e\n\u003cli data-start=\"230\" data-end=\"387\"\u003e\n\u003cstrong data-start=\"232\" data-end=\"258\"\u003eCheck Valve Technology\u003c\/strong\u003e: Equipped with an integrated check valve, it prevents backflow and water drainage, ensuring efficient and waste-free irrigation.\u003c\/li\u003e\n\u003cli data-start=\"388\" data-end=\"558\"\u003e\n\u003cstrong data-start=\"390\" data-end=\"409\"\u003eConsistent Flow\u003c\/strong\u003e: Delivers 0.53 GPH flow rate at 12-inch emitter spacing, making it ideal for evenly spaced, consistent watering for gardens or landscaping projects.\u003c\/li\u003e\n\u003cli data-start=\"559\" data-end=\"698\"\u003e\n\u003cstrong data-start=\"561\" data-end=\"585\"\u003eDurable Construction\u003c\/strong\u003e: The 17mm tubing is built to endure tough outdoor conditions, offering long-lasting reliability and performance.\u003c\/li\u003e\n\u003cli data-start=\"699\" data-end=\"850\" data-is-last-node=\"\"\u003e\n\u003cstrong data-start=\"701\" data-end=\"731\"\u003eEco-Friendly and Efficient\u003c\/strong\u003e: Perfect for sustainable irrigation, using reclaimed water efficiently while maintaining healthy, thriving landscapes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eQ\u0026amp;A\u003c\/h5\u003e\n\u003cp data-start=\"0\" data-end=\"373\"\u003e\u003cstrong data-start=\"0\" data-end=\"121\"\u003eQ: What is the Netafim Techline HCVXR 17 mm Reclaimed Purple Stripe Check Valve Dripline - TLHCVXR-RW5-1205 used for?\u003c\/strong\u003e\u003cbr data-start=\"121\" data-end=\"124\"\u003eA: This dripline is designed for reclaimed water irrigation systems, featuring a 17mm diameter, 0.53 GPH flow rate, 12-inch emitter spacing, and a built-in check valve to prevent backflow, ensuring efficient and safe irrigation with reclaimed water.\u003c\/p\u003e\n\u003cp data-start=\"375\" data-end=\"700\"\u003e\u003cstrong data-start=\"375\" data-end=\"488\"\u003eQ: What are the key features of the Netafim Techline HCVXR Reclaimed Check Valve Dripline - TLHCVXR-RW5-1205?\u003c\/strong\u003e\u003cbr data-start=\"488\" data-end=\"491\"\u003eA: This dripline includes a check valve to prevent drainage, a 0.53 GPH flow rate, 12-inch emitter spacing, and a 500 ft. length, all marked with a purple stripe for easy identification of reclaimed water use.\u003c\/p\u003e\n\u003cp data-start=\"702\" data-end=\"1016\"\u003e\u003cstrong data-start=\"702\" data-end=\"785\"\u003eQ: How does the Netafim Techline HCVXR Check Valve Dripline improve irrigation?\u003c\/strong\u003e\u003cbr data-start=\"785\" data-end=\"788\"\u003eA: The check valve stops water from flowing backward, ensuring consistent water delivery and preventing waste, while the 12-inch spacing and 0.53 GPH flow rate provide efficient water use for landscapes or agricultural projects.\u003c\/p\u003e\n\u003cp data-start=\"1018\" data-end=\"1223\"\u003e\u003cstrong data-start=\"1018\" data-end=\"1072\"\u003eQ: Is the Netafim Techline HCVXR Dripline durable?\u003c\/strong\u003e\u003cbr data-start=\"1072\" data-end=\"1075\"\u003eA: Yes, it is built with durable materials that resist UV damage and clogging, offering reliable performance for reclaimed water irrigation systems.\u003c\/p\u003e\n\u003cp data-start=\"1225\" data-end=\"1473\"\u003e\u003cstrong data-start=\"1225\" data-end=\"1316\"\u003eQ: How easy is it to install the Netafim Techline HCVXR Reclaimed Check Valve Dripline?\u003c\/strong\u003e\u003cbr data-start=\"1316\" data-end=\"1319\"\u003eA: Designed for easy installation, this dripline can be quickly set up in reclaimed water systems, ensuring efficient irrigation with minimal maintenance.\u003c\/p\u003e\n\u003ch5\u003eMaintenance Tips\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-start=\"151\" data-end=\"283\"\u003e\n\u003cstrong data-start=\"154\" data-end=\"176\"\u003eRegular Inspection\u003c\/strong\u003e: Check the tubing for clogs, cracks, or any visible wear, especially around the emitters and check valves.\u003c\/li\u003e\n\u003cli data-start=\"284\" data-end=\"406\"\u003e\n\u003cstrong data-start=\"287\" data-end=\"307\"\u003eFlush the System\u003c\/strong\u003e: Periodically flush the dripline to remove any debris or mineral buildup that could obstruct flow.\u003c\/li\u003e\n\u003cli data-start=\"407\" data-end=\"555\"\u003e\n\u003cstrong data-start=\"410\" data-end=\"434\"\u003eTest the Check Valve\u003c\/strong\u003e: Ensure that the check valve is functioning correctly by preventing backflow and maintaining pressure within the system.\u003c\/li\u003e\n\u003cli data-start=\"556\" data-end=\"681\"\u003e\n\u003cstrong data-start=\"559\" data-end=\"579\"\u003eMonitor Pressure\u003c\/strong\u003e: Ensure the system operates at the recommended pressure to avoid uneven water distribution or damage.\u003c\/li\u003e\n\u003cli data-start=\"682\" data-end=\"817\"\u003e\n\u003cstrong data-start=\"685\" data-end=\"704\"\u003eProtect from UV\u003c\/strong\u003e: Store unused dripline in a shaded or covered area to prevent UV degradation and maintain long-term performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv id=\"aircall-extension-app\"\u003e\u003c\/div\u003e\n\u003cdiv id=\"aircall-extension-app\"\u003e\u003c\/div\u003e","brand":"Netafim Irrigation","offers":[{"title":"Default Title","offer_id":52352595099929,"sku":null,"price":302.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/6081\/1289\/files\/Netafim-TLHCVXR-RW5-1205-NetafimTechline.png?v=1778048763","url":"https:\/\/forbiddenkeystopower.com\/products\/netafim-tlhcvxr-rw5-1205-netafim-techline-hcvxr-17-mm-reclaimed-purple-stripe-check-valve-dripline-0-53-gph-12-in-spacing-500-ft","provider":"The Forbidden Keys to Power","version":"1.0","type":"link"}